What pressure should a Worcester expansion vessel be?

What pressure should a Worcester expansion vessel be?

When the heating system is cool, the pressure should be between 1 and 1.5 bar on the pressure gauge (the indicator needle would usually be in the green section). If pressure is below 0.5 bar (down in the red section), water has been lost from the system and must be replaced.

What pressure should a Worcester 24cdi boiler be?

Ideally the pressure should be between 1.0 and 1.5 bar but just under 1.0 is fine. The boiler will continuew to work until it drops to between 0 and 0.5 bar.

How do you lower the pressure in an expansion vessel?

If it’s above 2 bars, you’ll need to reduce the pressure. Ensure the filling loop or relief valve is tightly closed. Bleed your radiators to release trapped air from the heating system. Check to see if the boiler pressure returns to its correct setting.

What pressure should boiler be when off?

between 1 and 1.5 bars
What pressure should my boiler be when the heating is off? Boiler pressure should generally be between 1 and 1.5 bars when central heating is turned off. The needle of the pressure gauge should remain above the lower limit set by your boiler manufacturer at all times.

Do I need to replace my Worcester Bosch pressure relief valve?

1. You need to specify the model, and preferably year, of the boiler, as some Worcester Bosch boilers are so constructed that the boiler needs to be removed to fix the pressure relief valve (PRV). 2. If its is still leaking at 1 bar pressure, then you will almost certainly need a new PRV.

When do I need to replace my expansion vessel?

The first and only time you need to replace an expansion vessel is when the membrane is perforated, and water is allowed to go into the air chamber, thus preventing anywhere for the expanded water to go, resulting in it blowing past the pressure relief valve.

How do I recharge the pressure vessel?

Recharging the pressure vessel isn’t quite that simple – see faq section under Boiler Pressure Problems. You will need a new pressure relief valve – once they’ve let water out they usually stay leaking. The expansion vessel pressure should be about 0.8 Bar with the boiler pressure gauge showing zero.

What should the pressure be on a boiler expansion vessel?

The expansion vessel pressure should be about 0.8 Bar with the boiler pressure gauge showing zero. Open valve by turning red part until water slows/stops. Use grips to remove red part of safety valve or disconnnect outlet pipe and remove clip and entire valve (O ring fitting).