Where are tamper-resistant receptacles needed?
Where are tamper-resistant receptacles needed?
Tamper-resistant receptacles are also now required in hotel rooms, child care facilities, preschools, elementary education facilities, waiting areas in medical and dental clinics, dormitories, and waiting areas in any place of assembly, anywhere children may not be closely supervised.
Are tamper proof outlets code?
Tamper-resistant (TR) receptacles were first required within the 2008 edition of the National Electrical Code (NEC).
What is the code for electrical outlets?
The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned at least every twelve feet measured along the floor line.
Is TR receptacle required?
Q. Where are tamper-resistant receptacles required? A. All nonlocking type 15A and 20A, 125V receptacles in the following areas of a dwelling unit [210.52] must be listed as tamper-resistant [406.12].
Do I need tamper resistant outlets in garage?
Receptacles for garage-door openers located more than 5½ feet above the floor are required to be tamper-resistant. Floor receptacles located more than 18 inches from the wall are required to be tamper-resistant, even though 210.52 does not specify these receptacles as required receptacles.
Do I need weather resistant GFCI in bathroom?
Is there a Code requirement? GFCIs are required by the National Electrical Code to be installed in wet or damp locations. This would include kitchens, bathrooms, basements, laundry rooms, garages, porches and any other areas where a water source is present.
Are garage outlets required to be tamper resistant?
How do tr outlets work?
Tamper-resistant outlets are designed to prevent kids from hurting themselves while fidgeting with an outlet. They have two spring-loaded shutters that close the slots when you remove a plug. When you insert a plug, both shutters compress and the slots open again to accept the plug.
What is code for distance between outlets?
12 ft.
Wall receptacles serve spaces for 6 ft. on each side of receptacle. Therefore, max. spacing between wall receptacles is 12 ft.
Why are receptacles upside down?
Electricians may position the outlet in an upside-down position so that you can quickly identify the switch-controlled receptacle. Since it stands out visually to most people right away – it provides convenience to the occupants to easily remember which outlet is switch controlled.
What does TR mean on electrical outlet?
Tamper-Resistant Outlets
TR outlets protect the outlet from tampering and user from shock via spring-loaded shutters. TR-rated outlets feature “TR” engraved into the outlet faceplate, typically between the two prongs. The shutters remain closed until the proper plug is inserted.
How many outlets can be on a 20 amp circuit in a garage?
ten outlets
The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle.