Do you have to gland SWA cable?
Do you have to gland SWA cable?
Glands should always be fitted at both ends to correctly terminate the cable into the enclosure, if the armour isnt being used as the cpc then an earth banjo at the supplly end will do. Whatever made you think that one end need not be glanded.
Do you have to earth both ends of SWA cable?
It should be earthed at least at the source end, as it is clearly an exposed conductive part. Most calculation methodologies and much tabulated cable data assumes that the armour is reliably connected to earth at both ends.
Does Armoured cable need glands?
Steel Wire Armoured (SWA) cable is a versatile and robust cable ideal for outdoor electrics. However it is difficult to work with due to its size and inflexibility, and also the requirement that all connections must be correctly terminated using appropriate termination glands.
Can you use plastic glands with Armoured cable?
You may not have come across PVC Enclos or Plastic Rotary isolators but if you connect to them with SWA having a conductor available for an Earth then there is no requirment to connect the “insulated” armour to anything and if you do there will be no increase in safety, in fact you could introduce an earth path for …
Does SWA Armour have to be earthed?
AFAIK, it must always be earthed, and at the source end. I could understand the load end of the armour being totally isolated depending on the load end earthing system.
Can you use plastic glands on SWA?
as armour on SWA is not exposed there is no requirment to connect it unless you are using it as a earth conductor.
How do you run Armoured cable to a shed UK?
How can I run an armoured cable to my shed?
- Step 1: Contact Building Control.
- Step 2: Ensure a safe work environment.
- Step 3: Check your consumer unit has enough spare capacity.
- Step 4: Measure the distance from the consumer unit.
- Step 5: Choose the right cabling.
Can I use plastic glands on SWA?
How do I install the cable gland?
INSTALLATION INSTRUCTIONS 1.Select the correct cable gland size using physical dimensions of the cable cross-referenced against the selection table opposite. 2. Separate the cable gland into two sub-assemblies A and B by unscrewing the entry component (1) from the body (2).
Can SWA cable be taken into an enclosure without gland?
Taking SWA into an enclosure without the use of any form of gland is also unacceptable since the weight and rigidity of the cable means it must have mechanical support and fixing at entry to an enclosure. This is a picture of the seven parts of the somewhat inappropriately named three part gland kit.
How do you attach a conduit gland to a box?
Now the gland is fitted to the cable we can attach it to the actual box or panel that the cable is intended to connect to. For the smaller SWAs a 20mm knock out makes an ideal termination hole. Metal boxes often have pre-made holes ready to take SWA and conduit glands.
Why is SWA cable so difficult to terminate?
Terminating SWA Steel Wire Armoured (SWA) cable is a versatile and robust cable ideal for outdoor electrics. However it is difficult to work with due to its size and inflexibility, and also the requirement that all connections must be correctly terminated using appropriate termination glands.