How to Unlock a Johnson Controls Thermostat
- Press and hold the “C/F” button on the front of the thermostat until the configuration menu appears—roughly 8 seconds.
- Tap “C/F” until “Lockout” appears on the screen.
- Press the “Up” or “Down” buttons until “Lockout Level 0” appears on the screen.
How do I set the temperature on my Johnson Controls thermostat?
Press the Menu icon. Press Setpoints and then Temperature. Select the setpoint to adjust and change as preferred. Press Save and the back arrow to return to the previous screen.
What is a fan coil thermostat?
These thermostats control temperatures of two- and four-pipe fan coil unit (FCU) systems. FCUs use a coil and fan to heat or cool a room. These thermostats allow for multiple settings of the fan’s output to gradually heat or cool the room to the desired temperature.
How do you lock a glas thermostat?
Lets you enable a passcode to lock your device from unapproved changes to your temperature, settings, setpoints, or schedule. To set a passcode, navigate to Settings > General > Passcode.
What is reverse acting thermostat?
That is a definition. The thermostat rate reverses. As the set-point is reached, a thermostat that decreases or switches off its output. The thermostat that controls a typical house furnace is reverse-acting since it turns off the furnace when the set-point is reached.
What does FCU mean in HVAC?
fan coil unit
A fan coil unit (FCU) is a device that uses a coil and a fan to heat or cool a room without connecting to ductwork. Indoor air moves over the coil, which heats or cools the air before pushing it back out into the room.
How does FCU unit work?
A fan coil unit (FCU) contains a fan which draws the air in a space into the unit then blows it over a cooling or heating coil. The air comes out of the FCU either cooler or hotter than before. Each FCU is provided with a small supply of outside air to ensure adequate ventilation.
Why choose Johnson Controls for your commercial thermostat?
Temperature is arguably the most important component in a building’s environment. The comfort of its occupants depends on an indoor climate that adapts to their needs. That core competency is at the heart of Johnson Controls. Our commercial thermostats provide unprecedented accuracy, efficiency and energy savings.
What is the FCP 7-day programmable and FCP non-programmable thermostat?
Controlling 2-pipe or 4-pipe fan coil units is now easier than ever, thanks to the versatile FCP 7-Day Programmable and FCP Non-Programmable Thermostats. They’re designed to be easy to self-install, and they’re highly configurable.
What is a T46 thermostat used for?
The T46 Series Thermostat is used to control line voltage, fan coil, and heating zone valves on heating, cooling, and combination heating and cooling systems. Models are available with single-pole, single-throw (SPST) or single-pole, double-throw (SPDT) contact action for standard duty (nominal 1/4 hp, 6 A non-inductive) applications.
What is the tec3000 series smart thermostat?
A full-color touchscreen makes the TEC3000 Series Smart Thermostat and HVAC Equipment Controller easy to configure and control. Available in networked, wireless or standalone models, it’s ideal for both traditional and smart equipment.