What does the yellow trouble light on my DSC keypad mean?
What does the yellow trouble light on my DSC keypad mean?
The yellow trouble light indicates a system problem of some sort. To find out the cause of the trouble light, press *2 on your keypad. could be a phone line issue or the system could not connect to a monitoring station or self dial attempt failed. 5 or 6 means there is an issue with a zone or sensor or related wiring.
Why does my tamper alarm keep going off?
Spider webs or insects on a detector can also be a problem causing your burglar alarm to go off intermittently. Other common problems can be caused by loose detector casings as they have sensitive tamper switches and cables that might be slightly damaged overtime causing the alarm readings to fluctuate.
What does alarm tamper mean?
A tamper on an alarm system prevents it from being opened without the system owner being informed. The tamper, like any burglary zone, activates an alarm when opened while the system is armed. A panel tamper is activated when the cover on an all-in-one system is opened.
How do you clear the trouble light on a DSC alarm?
The trouble light is an indication that something is not functioning properly on your DSC security system. When a trouble is present the system trouble indicator light will illuminate and the keypad will beep every 10 seconds. To silence the trouble beep simply press the # key on the keypad.
How do you bypass a security system?
Bypass a Zone
- Enter the following: Your 4-digit code. The number 6 (bypass button) Two-digit zone number of the zone you want to bypass. (01, 02, 03, etc.)
- Repeat this process for all zones you would like to bypass.
- Once your system is disarmed, this process will need to be repeated in order to arm your system again.
What does bypass mean on alarm system?
“Bypassing” a device is a step in which you instruct your armed Ring Alarm system to ignore a particular sensor for the specific time the sensor is armed. Example: you’re at home and want to arm the exterior sensors but leave the back door open for the dog.
Is there a replacement keypad for my power 832?
Most newer DSC keypads are backwards-compatible with older models of panel, so you can probably find a replacement for a worn-out keypad. Depending on the age and condition of your Power 832 system, this could be a good option
How many keypads can a DSc 832 system support?
The 832 system can support up to a total of 8 keypads in any combination. The basic DSC 832 panel has 8 on-board zones for burglary devices, plus a dedicated fire zone via the PGM terminals.
How does a DSc 832 work with a 4-wire smoke detector?
Using one of the two PGM Outputs allows the DSC 832 to work with 4-wire smoke detectors. The PGM out provides switched power for resetting the 4-wire smokes, while one of the standard zone inputs is programmed for the fire alarm function.