LHS Cable is a smart sensing product aimed at providing early detection of fire or overheating in adverse environmental conditions within areas of limited access and surveillance. These unique cables and associated systems can detect heat anywhere along the length of the cable by detecting changes in temperature.
What is LHD cable?
Digital linear heat detection cable is comprised of a pair of twisted low resistance, tri-metallic conductors, sheathed in advanced temperature sensitive polymers. …
How does protectowire work?
How linear detection works: If a portion of the Protectowire Linear Heat Detector is exposed to heat above it’s rated alarm temperature the heat sensitive polymer breaks down and a short occurs at that point. This bypasses the end line resistor greatly increasing the current flow through the loop.
What is fire alarm cable?
Fire alarm cables are multiconductor electronic cables with fire-rated protection. These products have multiple applications and variations that designate where a type of wire is installed.
What is detection wire?
Detect Wires tool is used to vectorize wires and classify points on wires of a powerline. The most important parameter controlling wire detection is Max gap which defines the maximum gap between consecutive laser points on a wire.
What is Call Point Fire Alarm?
Recognisable usually by its green colour, the fire alarm call point is the enclosure that houses a button to activate a fire alarm. Usually, the user will break the glass and press the emergency button centred in the middle of the unit.
How does a flame detector work?
Infrared flame detectors – These sensors operate by using an infrared band. A small thermal imaging camera in these detectors can instantly detect the presence of hot gasses released anywhere near the infrared detector. Infrared waves can penetrate dust, smoke, fuel particles and oil films.
What is a Vesda system?
VESDA Systems are aspirating smoke detection used for early warning applications where response to a fire is critical. The VESDA detectors are able to communicate this information to a fire alarm control panel, a software management system or a building management system via relays or a High Level Interface (HLI).
Is fire alarm cable required to be in conduit?
Cables shall be installed in metal raceways or rigid nonmetallic conduit where passing through a floor or wall to a height of 2.1 m (7 ft.) above the floor, unless adequate protection can be afforded by building construction such as detailed in 760.130(B)(1), or unless an equivalent solid guard is provided.
Can you run fire alarm cables with data cables?
Communications raceways are now permitted for use with Class 2 and Class 3 cables (Article 725), power-limited fire alarm cables (Article 760), communications cables (Article 800), CATV cables (Article 820) and low-powered network-powered broadband communications cables (Article 830).
What is fire hooter?
The fire alarm Hooter and Sounder are Audio indications to fire Signals. Alarm Hooter Plays a crucial role of vital importance by Creating a Hooter Like Sound as and when the control monitoring Panel Detects a fire signal from any zone.