What is R-404A used for?

What is R-404A used for?

R-404A:Refrigerant for packaged air conditioners, commercial air-conditioning and vending machines. R-404A:Refrigerant for showcases, vehicle-mounted refrigerators, and commercial freezers.

What is Forane refrigerant?

Forane® 134a (R-134a) is a non-ozone depleting HFC with properties very similar to R-12. It can be used both as a pure refrigerant Forane® 22. Forane® 22 refrigerant (R-22) is used in a broad range of applications, including residential and commercial air …

What is the best replacement for R-404A?

What are the best replacements for R404A? For cold rooms and other small to medium commercial refrigeration applications, R448A and R449A and R452A or R134a are excellent alternatives to R404A, with from 50 to 65% reduction in GWP.

What type of lubricant must be used for a R-404A system?

Mineral Oil
Mineral Oil: Mineral oil has been the lubricant of choice for systems utilizing many of the CFC and HCFC refrigerants. Both the CFCs and HCFCs tend to have adequate miscibility with mineral oil, helping to ensure acceptable oil return under normal operating conditions.

Is R404A a blend?

A Widely Used and Thoroughly Trusted Refrigerant Freon™ 404A (R-404A) is a blended hydrofluorocarbon (HFC) refrigerant comprised of R-125, R-134a, and R-143a. It was designed to replace R-502 and R-22 used in commercial refrigerator equipment for low and medium temperature ranges.

Is R404A ozone friendly?

The refrigerant R404a is an alternate refrigerant to CFCs and HCFCs as they are ozone friendly and have less Global Warming Potential (GWP) than R12 and R134a.

What is Forane R-22?

Forane® 22 refrigerant (R-22) is used in a broad range of applications, including residential and commercial air conditioning, refrigeration, chillers, room air conditioning, heat pumps, transport refrigeration, and other comfort cooling and refrigeration applications.

Is Forane 22 the same as R-22?

Forane® 22 refrigerant (R-22), an HCFC, has properties providing for a broad range of applica- tions, including residential air conditioning, refrigeration, and other cooling applications.

Is r404 banned?

R404A can be used until the end of 2019 but production levels are decreasing rapidly with price and availability becoming a big issue for end users. Recovered or reclaimed R404a can be used until the end of 2030, then all replacement R404a will be banned. HFC drop-in replacements for R404A.

Can R404A replace r290?

Compressors manufactured by Embraco labelled r290 are exactly the same as their equivalent r404a compressors. So yes, you can empty an r290 system and replace it with r404.

Can you use R404a with mineral oil?

Said Terry, “While these refrigerants are not totally miscible with AB and mineral oils, total miscibility is not a requirement for oil transport in the applications the refrigerants are designed for.”

What are normal operating pressures for 404A?

R404a Refrigerant Pressure Chart

Temperature (Fahrenheit) Temperature (Celsius) R404a Pressure
– 35°F – 37.2°C 6.8 psi
– 30°F – 34.4°C 9.6 psi
– 25°F – 31.7°C 12.7 psi
– 20°F – 28.9°C 16 psi

author

Back to Top