What should boiler aquastat be set at?

What should boiler aquastat be set at?

In most cases, the high-limit temperature setting on an aquastat should be between 180 and 200 degrees Fahrenheit. If the aquastat is set at 200 degrees Fahrenheit as the high-limit setting and the pressure valve begins to leak, set the temperature back to 195 degrees Fahrenheit.

What is the differential setting on a boiler?

When boiler temperature is rising: on an aquastat control, the “DIFF” or differential control dial specifies the amount above the LO or “Low Limit” to which boiler temperature must rise before the burner will turn off and the circulator will be allowed to run.

What temperature should my indirect water heater be set at?

120°F
Water temperature from the heat source / boiler to the indirect water heater is controlled by an immersion aquastat. This control operates the circulator, and provides limited control for domestic hot water temperature. The proper temperature setting for domestic hot water use is 120°F/49°C.

What are the two functions of the high limit aquastat?

In hydronic heating we use both – the aquastat to control boiler water temperature, and the thermostat to control room temperature. There are two parts to the word – “aqua” and “stat.” Aqua means water. Stat means switch.

What temperature should my boiler show?

For a modern combi boiler, the radiator heating temperature should be set at or around 75 degrees celsius for the best efficiency and performance.

What is the best setting for my boiler?

To maximise efficiency, we recommend setting your radiator dial to 75 degrees and your hot water to 60 degrees. Once you’ve got your boiler running at the optimal temperature, you’ll want to set the timer for when you need heating the most.

What should the high limit be set to on a boiler?

Temperature expectations for your boiler If you can raise the temperature manually, do not set it any higher than 210°F (which is often the limit), and try to remain down at 190°F if you need the extra heat. Once a boiler starts to go over 212°F, you can face serious problems.

What is the purpose of the low limit in an Aquastat?

The low limit is intended for tankless domestic hot water—it ensures that boiler water is always warm enough to heat the domestic hot water. Many aquastats also have a differential (“diff”) control which determines the size of the range around the “low” and/or “high” controls.

What temperature should oil boiler be set at?

Setting the boiler temperature As a rule, setting your heating control to 75 degrees should be sufficient to give you a perfectly warm house, while also allowing your boiler to run as economically as possible. Once this is set, you shouldn’t need to adjust it.

What happens if you set the aquastat to too high?

Watch out: Setting the “HI” too high on the aquastat can result in over-temperature in the heating boiler and can result in dumping water and temperature and pressure at the relief valve. If your TP valve was not leaking before and it begins to drip when you set up the HI to 200 F, step the HI back to 195 and try that setting.

What temperature should my aquastat Hi be set at?

Normally for boiler efficiency we like to set the aquastat HI to 200. If your aquastat HI limit is set to 200 F (about as high as is safe), as long as the boiler temp stays above about 180F the burner won’t come on until boiler water drops below that point.

What does the low limit control on an aquastat?

Basicly the Low Limit part of the aquastat controls both the the burner (when there is no call for heat on the TT terminals) and the circ. When the Low Limit contacts are closed and running the burner (to keep a minimum temperature for the tankless), the other contact is open preventing the circ. from running.

Can we adjust the heating aquastat control to save money?

But with a little thought, we can adjust these HI LO DIFF settings and thus set the heating aquastat control so as to save a bit more on heating cost, and/or we can set the control to give us a bit more hot water where a tankless coil is installed.