What does Kaic mean on Breakers?

What does Kaic mean on Breakers?

Also known as KAIC (Kilo Ampere Interrupting Capacity), this is the maximum the breaker is rated to which means it’s important to ensure that your maximum available fault current is less than this rating of the equipment at the point of installation.

What is fully rated panel?

Fully rated panels are breakers rated for the available fault current that is at the terminal of the breaker. These are the more expensive to make, especially as you get higher and higher in fault current. Series rated panels, however, rely on the main breaker to handle most of the fault current.

Is Siemens a good breaker panel?

The bottom line is that both Square D and Siemens are high quality brands that manufacture safe and reliable electrical panels for residential purposes. They both offer a range of panels that meet any household needs, so if you’re trying to decide between them, keep in mind that the differences are not functional.

What is the AIC rating of a circuit breaker?

AIC: Ampere Interrupting Capacity The AIC rating indicates the maximum available fault current (in amps) that an overcurrent protection device (circuit breaker, fuse, etc.) will safely clear when a fault is applied at the load side of the overcurrent protection device.

What does 10kA mean on a circuit breaker?

The 10 kA you see on a circuit breaker is the interrupting rating of the circuit breaker, that is, the largest current that it can safely open. It is usually written as 10 kA rms symmetrical. The rms indicates that it is rated to interrupt 10 kA root mean square current.

What are the standard AIC ratings for panels?

Minimum AIC ratings for the panel should be 10,000 AIC for 120/208 volt panels, and 14,000 AIC for 277/480 panelboards.

Can I use a GE breaker in a Siemens panel?

Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. If the wrong breaker is used it could fail to break (shut off power) during a surge.

Is SCCR the same as Kaic?

AIC (kAIC) applies to protective interrupting devices such as circuit breakers and fuses. SCCR applies to complete pieces of equipment such as motor control enclosures containing breakers/fuses, contactors, or solid state devices used for motor control or components combined into a control scheme.

How many amp is 10kA?

“10KA” means 10,000 amps.

What does 10kA stand for?

10kA equals 10,000 amps.

author

Back to Top