What is a supervisory switch?
What is a supervisory switch?
What is a supervisory switch? Supervisory switches detect the status of a fire sprinkler system and relay that information to a central, proprietary, or remote monitoring center or sound a local alarm. To properly maintain a fire sprinkler system, you need information.
What is supervisory switch in fire alarm?
Valve supervisory switches are used to monitor the open or closed position of the valves that control the water supply in the fire sprinkler system. Supervisory pressure switches monitor the status of the system air pressure in dry and pre-action systems.
What is flow switch in fire fighting?
Flow Switch – Explosion Proof The switches are actuated when a flow of 10 gallons per minute (38 Lpm) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period.
What is purpose of tamper switch?
A tamper switch is a mechanical and electrical device connected to a fire protection valve that signals a warning if the valve partially or fully closes. Regardless of the type of tamper switch, they all function similarly. The tamper switch features an actuating unit, usually a lever or cable with a resting position.
What are supervisory devices?
88.2 Automatic Extinguishing System Supervisory Device. A device that responds to abnormal conditions that could affect the proper operation of an automatic sprinkler system or other fire extinguishing system(s) or suppression system(s), including, but not limited to: control valves. pressure levels.
What is a waterflow switch?
A water flow switch in an automatic fire sprinkler system is an electro-mechanical device and alarm initiating device that is installed typically in the main (above an alarm valve) or in a branch of the sprinkler system that is used to detect water flow and therefore the activation of a fire sprinkler head or remote …
What is the difference between pressure switch and flow switch?
Pressure Switches are activated when you reach a certain pressure: between 500-700 PSI. When the pressure meets this threshold, the switch is used to activate the burner for hot water. Flow Switches are activated by the recognition of water flow. The pressure is usually lighter, lower than 500 PSI.
How many types of flow switches are there?
There are two main flow switch types — the paddle design and the piston or shuttle design. The paddle design of a flow switch places a hinged or spring-mounted paddle in the liquid flow path. Media flowing at the target rate holds this in position.
What is butterfly valve with tamper switch?
Butterfly valve With Tamper Proof Switch offers precision flow control of fluids and gas. This valve is suitable for both indoor and outdoor use and can also be used as a control valve in fire protection systems. Dual supervisory switches and wiring make it easy to connect the Butterfly valve to a fire control panel.
What is fire supervisory?
Supervisory – A supervisory condition means there is an issue with a system, process, or equipment that is monitored by the fire alarm control unit (see supervision section). An example of this would be a sprinkler system valve being closed, this would show up as a supervisory signal on the control unit.
Is fire pump running alarm or supervisory?
When connecting to the fire alarm system, NFPA 72:23.8. 5.9 requires that any signal other than a “pump running” signal be supervisory. NFPA 20:10.4. 7 requires four signals to be transmitted remote from the pump when the pump room is not constantly attended.
What is a supervisory switch in sprinkler system?
A class of electronic monitoring equipment, supervisory switches provide information about the state and functionality of the sprinkler system. There is no real difference between a supervisory switch and a tamper switch—because a tamper switch is a supervisory switch.
What is the purpose of a supervisory pressure switch?
Usually a supervisory pressure switch is used to monitor leaks in the system. • A pressure switch is connected to the alarm port of the alarm check valve. When the fire sprinkler head is activated, the alarm check valve opens.
What is the difference between a supervisory switch and a tamper switch?
There is no real difference between a supervisory switch and a tamper switch—because a tamper switch is a supervisory switch. These devices send a trouble signal whenever a fire sprinkler control valve is closed.
How does a fire protection tamper switch work?
Think of it like a light bulb: when the light switch is on, a circuit is formed and the bulb shines brightly. When the switch is turned off – or, in the case of a fire protection tamper switch, the valve closes – the circuit is broken. For tamper switches, this broken circuit creates a signal.