What is ULC S101?
What is ULC S101?
The standard used for fire-resistant ratings is CAN/ULC-S101, Fire Endurance Tests of Building Construction and Materials. This standard is critical for fire-resistance rating acceptance, as it is required by the National Building Code of Canada (NBC).
What is CAN ULC S114?
ULC CAN-S114. June 1, 2018. Standard Method of Test for Determination of Non-combustibility in Building Materials. This Standard provides a means of determining the non-combustible nature of elementary building materials. It shall be applied to materials used in the construction of buildings.
Can ULC S102 2 standard?
ULC Standards is pleased to announce the publication of the Eighth Edition of CAN/ULC- S102. 2:2018, Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies.
Can ULC S102 flame spread ratings?
The CAN/ULC-S102 test, when conducted in triplicate, reports Flame Spread (FS) and Smoke Development (SD) values for the specific product or assembly evaluated. The flame propagation along the material’s exposed surface is visually observed and average Flame Spread value determined.
Can ULC S102 10?
The method, designated as CAN/ULC-S102-10, “Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies”, is designed to determine the relative surface burning characteristics of materials under specific test conditions.
What does ULC mean?
Unlimited Liability Corporation (ULC) Definition.
What is the CAN ULC S114 test?
ULC Standards is pleased to announce the publication of the Fourth Edition of CAN/ULC- S114:2018, Standard Method of Test for Determination of Non-Combustibility in Building Materials. This Standard provides a means of determining the non-combustible nature of elementary building materials.
What is CAN ULC S524?
CAN/ULC-S524 covers the requirement for the design and installation of fire alarm systems with or without voice communications capability. This Amendment contains clarifications and revisions to enhance the requirements in the 2014 Edition.
Can ULC S102 2 fire rating?
The CAN/ULC-S102 equipment, known as the Steiner Tunnel, exposes the material, 21” wide x 24′ long sample size, to a 90kW flame for a 10-minute duration.
What is the can/ulc-s102-2 standard?
CAN-ULC-S102-2:Standard method of test for surface building characteristics of flooring, floor coverings, and miscellaneous materials and assemblies. CAN/ULC-S102-2 Fire tests on building materials–Standard Scope: This Standard is applicable to the finished surface or covering of a floor extending to a maximum depth of 65 mm.
What is the ULC code for flooring in Canada?
CAN/ULC-S102 and CAN/ULC-S102.2 for flooring products, are found throughout the various Canadian building codes which define the requirements for materials used as interior finishes, requirements are commonly based on the building’s occupancy type and the use/non-use of sprinklers.
What is a can S102 test?
The CAN/ULC-S102 test, when conducted in triplicate, reports Flame Spread (FS) and Smoke Development (SD) values for the specific product or assembly evaluated. CAN/ULC-S102 and CAN/ULC-S102.2 for flooring products, are found throughout the various Canadian building codes which define the requirements for materials used as interior finishes,