What is SE37 Abend in JCL?
What is SE37 Abend in JCL?
SE37. Explanation: The error occurred when an output operation was requested. The data set was on a direct access or magnetic tape device. This system completion code is accompanied by message IEC032I.
How do I fix my sb37 abend?
Steps to Fix Space Abend in PDS:
- Split (PF 2) the screen and select the UTILITIES option (option 3).
- Select the LIBRARIES option (option 1) on the Utility Selection Menu.
- Specify the name of the data set and enter C on the OPTION line.
- When the data set is compressed, you see the message: COMPRESS SUCCESSFUL.
How is GDG defined?
Generation Data Groups (GDGs) are group of datasets related to each other by a common name. The common name is referred as GDG base and each dataset associated with the base is called a GDG version. For example, MYDATA.
What is the difference between sb37 SD37 and SE37?
Disk volume out of space, cannot write output. SD37: Primary disk space was exceeded and either no secondary space allocation was specified, or it was insufficient. SE37: When there are no more volumes available.
How do I fix soc7 Abend?
Try to check what data you are passing as input, there must be some corrupt data which is causing soc7. Fix data issue. Soc7 abend will display the offset value(memory address) of your code where instruction is failing, figure out the statement where your code is failing using the offset value.
How do I fix soc7 abend?
What does the error code SB37 mean?
An SB37 abend indicates an out of space condition during end-of-volume processing. B37 Explanation The error was detected by the end-of-volume routine. This system completion code is accompanied by message IEC030I.
What does SB37 mean in MVS?
SB37 : End of volume ,if we have requested 1600 tracks , when the program tries to write more than 1600 tracks , the operation ended with SB37. As rightly said, we can quote as many cylinders as we may think would be optimal, but MVS allocates only to available extent.
What does Abend sd37 mean on a sequential file?
SYMPTOM: ABEND SD37, SB37 or SE37 ABEND on a Sequential Output File. CAUSE: The amount of data associated with the ABENDing sequential output file exceeded the capacity of the SPACE sub-parameter of the associated DD statement, or the available space on the Volume on which the sequential output file resides has been exhausted.
Does SB37 Abend in s050?
It abends in S050 with SB37. I changed to TRK (50,20) and rerun the job and ended okay. This was 1st and 2nd day. Later I change to CYL (5,2) in both step and it abend again in S050 with SB37 again. To solve it, I change to CYL (10,5) and it ended okay on 3rd day.