Why is my Alpha boiler not working?

Why is my Alpha boiler not working?

For a simple reset, Alpha recommends rotating the switch on the front of the boiler to position 3 (reset sequence). After 25-30 seconds, the boiler will attempt to restart. If the burner still won’t light, there’s a good chance it’s blocked with debris. Get a Gas Safe engineer to inspect and clean the burner.

Why does my Alpha boiler keep cutting out?

When the boiler pressure drops to around 0.6bar on the pressure gauge, your Alpha boiler will fail to operate. A sudden drop in pressure is a strong indication that there’s a link somewhere around the heating system. Radiators, various pumps and expansion vessels can all be prone to leaking.

How long do Alpha Boilers last?

Alpha warranty lengths Most brands offer around 5 years, with market leaders such as Worcester Bosch offering 10 years.

How do I lower the pressure on my Alpha boiler?

How to reduce your boiler pressure

  1. Switch off your boiler and wait for the heating system to cool.
  2. Identify and check the boiler pressure gauge.
  3. If it’s above 2 bars, you’ll need to reduce the pressure.
  4. Ensure the filling loop or relief valve is tightly closed.

Is Alpha evoke a good boiler?

This boiler is a highly efficient unit coming with an efficiency rating of 93%, making it an A rated boiler. This boiler has an output of 28kW and is ideal for those homes that do not have an excessive need for hot water….Alpha EVOKE 28kW Combi Gas Boiler.

Make Alpha
Is Condensing Condensing
Efficiency Rating 93%
Band Rating A Rated
LPG Compatible Yes

When should I press the reset button on my boiler?

Usually, when modern boilers need resetting they will display a fault code or begin to flash a red or green light. These signals indicate that your boiler senses a problem, which is why it has stopped working and needs to be reset.

Why is my Alpha boiler not heating up?

If your Alpha boiler problem is none of the above, there’s a good chance the diverter valve is to blame. This is emphasised more if you have no hot water, but your heating works. On some occasions, a stuck diverter valve can be freed.

What does a 47 fault code mean on an alpha boiler?

The most problem with Alpha boilers is red/yellow lights appearing on the display. Depending on which light is flashing, and how, will determine what the problem is. Either way, there’s a good chance you’re seeing a 47 fault code displayed on the boiler panel. When the A indicator is a solid red, this indicates that the burner has failed to light.

What does the NTC thermistor do on an alpha boiler?

The NTC thermistor (or thermocouple) on your Alpha boiler, monitors temperature. As water hits the desired temperature (set by your thermostat), it tells the boiler to switch off, or stop heating water. If the NTC thermistor is faulty, it won’t be sending the correct signals.

How do I Reset my Alpha gas boiler?

For a simple reset, Alpha recommend rotating the switch on the front of the boiler to position 3 (reset sequence). After 25-30 seconds the boiler will attempt to restart. If the burner still won’t light, there’s a good chance it’s blocked with debris.

author

Back to Top