How do you clean an ion source Agilent?
How do you clean an ion source Agilent?
Electron Impact Ion Source The recommended cleaning material is abrasive powder, aluminum oxide powder. Do not immerse filaments or lens insulators in solvent. If insulators are dirty, clean them with a cotton swab dampened with reagent-grade methanol. If that does not clean the insulators, replace them.
How do you clean mass spec source?
Use an abrasive slurry of the aluminum oxide abrasive with methanol or water. Cotton swabs work quite well with this abrasive slurry. These small cotton swabs enable the cleaning of corners inside the mass spec source.
How do you vent GCMS?
In the Instrument Control view, Instrument menu, click MS Vacuum Control to display the Vacuum Control dialog. Follow the instructions presented on the screen, and wait until the vent cycle is completed.
How do you pump down Agilent MSD?
Start the Agilent MassHunter GC/MS Acquisition software. In the Instrument Control view, from the Instrument menu, click MS Vacuum Control to display the Vacuum Control dialog. In the Vacuum Control dialog, click Pump Down and follow the system prompts.
How do I turn off Agilent GCMS?
- Just Before Shutdown. STEP 1: Perform an autotune (and air and water check for some models) and print the report.
- Shutting Down for a short time – A few minutes to a few hours. STEP 2: Set the Instrument to Vent.
- Shutting Down for a few Days.
- Shutting Down for a week or two.
- Shutting down for an indefinite length of time.
How do you clean an iron plate with salt?
Salt it up! Sprinkle a generous amount of salt on a sheet of paper. Then, run the warm iron over that sheet of paper, which assists in removing stains and other gunk. Run the iron a few times, then unplug the iron to let it cool. Once the iron is cool, wipe away the salt with a dry and soft cloth.
How do you clean a burnt iron with toothpaste?
Smear a small amount of white toothpaste on any affected areas of your iron soleplate. Leave it for a minute then use a clean cloth to wipe the toothpaste away. To finish things off, fill up your iron’s water tank, pop your iron on an old towel or similar, set it to steam, leaving it for a few minutes to work through.
How do you pump down GCMS?
In the Instrument Control view, from the Instrument menu, click MS Vacuum Control to display the Vacuum Control dialog. In the Vacuum Control dialog, click Pump Down and follow the system prompts.
What is the Agilent jetclean ion source for GC/MS?
The Agilent JetClean ion source for GC/MS significantly increases instrument uptime by reducing the need for frequent manual source cleaning. The unique Agilent QuickProbe GC/MS System enables real-time analysis using ultrafast sampling and GC separation followed by mass spectrometry detection.
What parts and cleaning supplies does agagilent offer for GC/MS?
Agilent offers a selection of replacement parts and cleaning supplies to help you keep your GC/MS running smoothly. Our range includes ion transfer capillary cleaning powder, ferrule kits, sorbent trap refills, and vacuum grease, among other products.
How often do you clean the source on the Agilent GC/MSD?
Since we started using the Agilent GC/MSD with JetClean, the source has been cleaned once in nine months. [That means] our instrument spends more time running samples and generating data—and our users spend less time having to remove, clean, and reinstall the source.”
What is the best ion source for GC/MS?
Agilent GC/MS ion sources are available in a variety of ionization modes for best performance in any matrix. The Agilent JetClean ion source for GC/MS significantly increases instrument uptime by reducing the need for frequent manual source cleaning.