How do I reset my Navien tankless water heater?

How do I reset my Navien tankless water heater?

To reset the water heater, press the Reset button. If resetting the water heater does not solve the problem, refer to the Troubleshooting section of this manual or contact Technical Support at 1-800-519-8794. To use water above 140 °F (60 °C) (up to 182 °F (83 °C)), you can use Commercial Mode.

How do you reset navien error?

To troubleshoot and fix Navien error code E030, switch the unit off for 30 seconds and then power it back on. Check the strainer and the heat exchanger. Clean the strainer and flush the heat exchanger if needed. The unit will cease working if the exhaust temperature exceeds 230°F (110 °C) for more than 10 seconds.

How do you troubleshoot a navien water heater?

Navien NPE Error Code E003

  1. Check if the manual gas valve is open.
  2. Check the main gas supply.
  3. For your safety and the health of your equipment, Call or Contact Hot Water Now!
  4. Verify that gas pressure is within operating range.
  5. Check Dual Venturi for proper operation.
  6. Check DIP Switch settings.
  7. Check if the igniter is sparking.

How often should Navien tankless water heaters be serviced?

Call Today for Navien Tankless Gas Water Heater Repair Annual maintenance is often essential for the manufacturer’s warranty policy. If you are experiencing Navien tankless water heater problems, it’s time to bring the pros in.

Where is navien reset button?

To reset the boiler, press the Reset button on the front panel.

What does E 003 mean on Navien tankless water heater?

Ignition failure in
Error Code E003. What it Means: Ignition failure in your tankless water heater. How to Fix: Confirm the main gas supply valve is open.

Does navien have a pilot light?

A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

What temperature should I set my Navien tankless water heater?

Hot water temperatures over 125°F can cause severe burns instantly or death from scalding. O With the Navien Water Heaters, the temperature has been preset at the factory to 120°F (NR, NR-A), 140°F (NP, NP-A). The PCB board will electronically control this temperature.

What does navien tankless water heater error code E001 mean?

Here is navien tankless water heater error code will help you much when you meet with the errors. The first code is E001. This error means the water is boiling in the heat exchanger. For quick troubleshooting, then you can do several steps. First, clean the water inlet strain.

How do I troubleshoot a navien water heater problem?

This means that at no cost to you, we may receive a small commission for made purchases. There are a large number of unique Navien error codes that help with troubleshooting the issue. Some problems can be solved with simply resetting the water heater unit (press the Reset button on the front panel) but other require more work.

What does E353 mean on a navien water heater?

Navien error code E353 indicates a problem with the water pressure sensor. An open or shorted sensor can cause Navien error code E353. Check and ensure the water pressure sensor and wiring are in good working condition, and there are no loose connections. If needed, replace the sensor.

What does E011 mean on a navnavien water heater?

Navien error code E011 means there is high pressure on the heating side. This error code may be fixed by switching off the unit, draining the water to release the pressure, and switching it back on. If the error persists, check the condition of the sensor.