What is a Class A pumper?

What is a Class A pumper?

Class A is a generic term similar to a “triple combination pumper.” Everyone knows the intent, but there are no formal definitions. Neither belongs in purchasing specifications. Today is not the first time generic, vague, or even regional terms have been used in apparatus specifications.

What is a Class A fire pump?

ORIGINS OF THE CLASS A PUMPER Between 1939 and 1947, national authorities on fire apparatus discussed the concept of a Class A pumper that would deliver 100% of its rated capacity at 150 psi NPP, 70% of rated capacity at 200 psi NPP, and 50% of rated capacity at 250 psi NPP.

What is the NFPA Standard for fire apparatus?

Referenced by fire departments throughout the United States, the NFPA 1901 defines the requirements for new automotive fire apparatus designed to be used under emergency conditions for transporting personnel and equipment, and to support the suppression of fires and mitigation of other hazardous situations.

What minimum pump capacity must a pumper have to meet the requirements of NFPA 1901?

300 gallons
The pumper shall be equipped with a water tank(s) that meets the requirements of NFPA 1901 Chapter 18 and that has a minimum certified capacity (combined, if applicable) of 300 gallons.

How many ladders should a pumper have?

Pumpers must carry one (each) roof ladder, extension ladder, and folding ladder. An aerial apparatus ladder complement is a minimum of 115 feet of ladders including at least two roof ladders, two extension ladders, and the folding ladder.

What is a pumper truck?

Pumper Truck They are similar to wagons and are typically fitted with a hose body, fire pump and a water tank. A pumper is seen at any fire scene where it is basically used to provide firefighters with important tools to help contain the fire and also to save the victims.

What is the minimum pump capacity for a fire department pumper?

NFPA standards require a Type 3 engine to have a minimum of a 500-gallon water tank and a pump capable of a minimum of 150 US gallons per minute at a pressure of 250 pounds per square inch. Type 3 trucks can be equipped with a power-take-off (PTO) pump.

How do I know what size fire pump I need?

For example, if you have a 40,000-square-foot building that is all ordinary group 1, the calculation would be 1,500 x 0.15 (density) = 225 + 250 (hose demand) = 475 gpm total for the fire pump. If the structure has multiple hazards, the hazard with the highest gpm calculation dictates the pump size.

How do you pump test a fire truck?

Run the pump for 20 minutes at 100% of rated capacity, with a net pump pressure of 150 pounds per square inch (psi). The NFPA requires this test for pumps rated for over 750 gpm. Immediately after the 20-minute test, run the pump for 5 minutes, at its rated capacity, at 165 psi.

What determines which hose load is carried on the pumper?

What determines which hose load is carried on the pumper? The type and size of fires expected to be encountered. Attack lines must supply a sufficient amount of water while remaining maneuverable.

Which of the following must be done before raising a ladder?

Which of the following must be done before raising a ladder? Check for overhead wires or electrical equipment. The Occupational Health and Safety Administration requires ladders be kept a distance of at least 10 feet (3 m) from: Electrical Lines.

How many feet of ground ladders are required on a ladder truck?

The minimum total length of ground ladders carried by a truck company, based on NFPA standards, is 115 feet. One problem with the minimum standard is that the minimum complement is based on total length and general type of ladder (one attic, two straight and two extension).

What is NFPA 20 for pump installation?

Standard for the Installation of Stationary Pumps for Fire Protection NFPA 20 protects life and property by providing requirements for the selection and installation of pumps to ensure that systems will work as intended to deliver adequate and reliable water supplies in a fire emergency. Current Edition: 2022

Are there any NFPA or ISO police for Class A pumpers?

There are no NFPA or ISO police, but there are tort lawyers. There is no formal description for Class A pumpers. NFPA 1901 does not address them nor does the ISO. But, purchasing specifications reference them on a daily basis.

Where can I find the Minimum Equipment List for pumpers?

The minimum equipment list for pumpers is found on page 23, paragraphs 5.8.2 and 5.8.3 of NFPA 1901.

What is the NFPA 1901 standard for fire apparatus?

Apparatus specifications (specs) published by fire departments, manufacturers, vendors, and consultants regularly refer to National Fire Protection Association (NFPA) 1901, Standard for Automotive Fire Apparatus, as they should. Some refer to a Class A pumper (Class A), which they shouldn’t.

author

Back to Top