What is a Socapex cable used for?

What is a Socapex cable used for?

Socapex is a brand of electrical connectors, known in the entertainment industry primarily for their 19-pin electrical connectors, commonly known as Socapex connectors, and used in film, television, and stage lighting to terminate the ends of a multicable.

How many circuits are in a Socapex cable?

6 circuits
Special socapex cable is used in the lighting world to carry 6 circuits of power inside 1 multipin cable. The Showsafe connector features 19 pins, an all-metal exterior and locking threads to keep the lines together.

What is the current rating of 2.5 mm cable?

around 23-25 amps
A 2.5mm cable is capable of supplying around 23-25 amps depending on the method of installation, so is fine, safe and compliant on a 20amp circuit breaker.

What is a Bates connector?

Bates Cables and Connectors (also called Stage Pin) are used to carry intermediate power loads. Connectors are sized for 100A, 60A and 20A. Bates cables are usually fed from Distro Boxes or sometimes directly from portable generators. The film industry typically uses 60A & 100A.

What is feeder cable?

Feeder cables are used to supply power from one part of a facility to another, from point A to point B. Perfect for providing temporary power service during construction or to supply power to specialized equipment. Primary feeder cables typically run between main switchboards and power distribution transformers.

What is the current rating of 2.5 mm twin and earth?

For example, the current-carrying capacity of 2.5mm twin and earth cable is 20 to 23 amps.

What is Edison connector?

An ordinary household electrical plug in the United States. Characterized by having two flat blades and a semi-round ground pin. A standard 15 amp plug has the two blades in parallel with each other.

What is the minimum wire gauge for stage extension cables?

100-foot Extension Cords

Current Draw Minimum Wire Gauge Voltage Drop
20A 10-gauge 4.00%
15A 12-gauge 5.00%*
12A 12-gauge 4.00%
10A 12-gauge 3.33%

What is feeder rating?

It means that if the selected ampacity of conductors (based on a particular ampacity table) is, for example, 225 A but the selected rating of the overcurrent device is 200 A, then the ampere rating of such circuit (feeder or consumer’s service) is 200 A.

What is the difference between a feeder and a branch circuit?

Branch circuits are not feeders. A branch circuit is defined as, the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). So, feeder conductors are conductors that are not service conductors and not branch circuit conductors.

What is a Socapex connector?

Initially developed in 1961, Socapex is a 19-pin electrical connector with a high strength-weight ratio that has become the standard for stage lighting multi-cable connections. Socapex is now manufactured by Aphenol Socapex along with electronic and fiber optic connectors, coaxial and high-speed specialty cables, antennas and interconnect systems.

What is the current rating of a single phase cable?

Cable Size & Current Rating Chart. Cross Section (mm2) Approximate Overall Diameter (mm) Current Rating. Single Phase (Amps) Three Phase (Amps) 1.5. 2.9. 17.5.

What is the current cable size & current rating?

Cable Size & Current Rating Chart Cross Section (mm2) Approximate Overall Diameter (mm) Current Rating Current Rating 300 27.9 458 394 400 30.8 546 467 500 33.8 626 533 630 37.6 720 611