What is the pressure of 134a at 100 F?

What is the pressure of 134a at 100 F?

50-55 psi

R-134a TEMPERATURE PRESSURE CHART (Tabla de Temperaturas y Lecturas)
100°F (38°C) 50-55 psi / 345-379 kPa 315-325 psi / 2172-2241 kPa
105°F (41°C) 50-55 psi / 345-379 kPa 330-335 psi / 2275-2310 kPa
110°F (43°C) 50-55 psi / 345-379 kPa 340-345 psi / 2344-2379 kPa
Ambient temp is the outside atmospheric temperature.

What is the temperature of r134?

R134a – TetraFlouroEthane Saturation Properties – Temperature Table (-40°C – 20°C)

Temp Pressure enthalpy (kJ/kg)
°C kPa hfg
-40 51.2 225.86
-36 62.9 223.35
-32 76.7 220.81

What is the temperature of R134a at 12 psig?

R134a Pressure Temperature Chart

Pressure Temperature Temperature
11 8.42 147.7
12 10.12 149.2
13 11.77 150.6
14 13.38 152.0

What should my gauges read on R134a?

It can be used for recharging refrigerant, or to diagnose an a/c system based on pressure readings from your gauges….R134a Pressure Gauge Chart.

Ambient Temperature (°F) Low Side High Side
80° 45-50 psi 175-220 psi
75° 40-45 psi 150-175 psi
70° 35-40 psi 140-165 psi
65° 25-35 psi 135-155 psi

What is the evaporation temperature of R134a at 0 psig?

-15°Fahrenheit.
The evaporation temperature of R134a at 0 psig is -15°Fahrenheit.

What should gauges read on 134a?

What are normal a C pressures?

An A/C System that is working properly should have 150 PSI on the high side and 30 PSI on the low side.

What is an R134A pressure chart?

Usually, it is called an AC pressure chart but because we are talking about the 134a refrigerant, therefore, we will address it as an R134a pressures chart. This chart provides us with the relation between temperature and pressure of the 134a refrigerant.

What is R134a refrigerant used for?

R134a refrigerant has zero ozone-depleting potential (ODP)) and is ubiquitous with the best refrigerant R12. R134a is the ideal refrigerant for working at high boiling and condensation conditions. R134a is a non-competitive refrigerant that has zero temperature “slip.”

Why is it important to know the R-134a level?

Understanding the pressure that your system is at as well as knowing what the saturation point is of R-134a will allow you to properly diagnose what is wrong with your system. Remember, that air conditioning is basically changing the pressure on the refrigerant until a state change is reached.

What is a refrigerant charge pressure chart used for?

This chart details how ambient temperature correlates with the system refrigerant charge pressure, and how it affects high and low side psi readings. It can be used for recharging refrigerant, or to diagnose an a/c system based on pressure readings from your gauges.

author

Back to Top