Maximum Allowable Pressure (psi) (kPa) | ||
---|---|---|
NPS | Outside Diameter | Schedule |
1 inch | 1.315 inch 33.4 mm | 4956 34172 |
1 1/4 inch | 1.66 inch 42.2 mm | 4133 28497 |
1 1/2 inch | 1.9 inch 48.3 mm | 3739 25780 |
What is the maximum pressure for Schedule 10 pipe?
Maximum working pressure of carbon steel pipe at temperature 400oF
Maximum Allowable Pressure (psi) | ||
---|---|---|
NPS | Outside Diameter | Schedule |
8 | 8.625 | 2307 |
10 | 10.75 | 2279 |
12 | 12.75 | 2160 |
What is the weight of Schedule 10 stainless steel pipe?
Stainless Steel Pipe -Type 304 Schedule 10S
Item # | Size | Weight |
---|---|---|
304-6000-6625-10S | 6 inches | 9.293 lbs/ft13.829508052 kg/m |
304-8000-8625-10S | 8 inches | 13.404 lbs/ft19.947350256 kg/m |
304-10000-10750-10S | 10 inches | 18.660 lbs/ft27.76914024 kg/m |
304-12000-12750-10S | 12 inches | 24.174 lbs/ft35.974876536 kg/m |
What grade of steel is schedule 40 pipe?
Material. Schedule 40 steel pipe is typically made from a low-carbon or mild steel. These steels are typically categorized by having a carbon content less than . 2 percent.
What is the difference between Schedule 40 and Schedule 80 steel pipe?
Schedule 40 pipe has thinner walls, so it is best for applications involving relatively low water pressure. Schedule 80 pipe has thicker walls and is able to withstand higher PSI (pounds per square inch). This makes it ideal for industrial and chemical applications.
What is the pressure rating for schedule 80 galvanized pipe?
Larger Schedule 80 pipe that is used for internal installation ranges from 2 inches to 3 1/2 inches in diameter. A 2-inch pipe is rated for 920 PSI of continuous service pressure and will burst at 7,340 PSI. Pipes 3 1/2 inches in diameter have a service rating of 990 PSI and a burst pressure of 7,950 PSI.
What is the pressure rating for Schedule 40 black steel pipe?
The pressure rating of schedule 40 black, or carbon steel pipe, varies with the inner and outer diameters of the pipe, ranging in value from 188 to 696 pounds per square inch gauge.
What is a schedule 80 pipe?
Schedule 80 PVC pipe denotes PVC pipe of a standard wall thickness. In pipe terms, “schedule” indicates the wall thickness. The thickness of the wall is responsible for the pressure capacity of the pipe. No matter what schedule of pipe is used, the outside diameter is standard and the inside diameter decreases as the schedule increases.
What is the temperature rating of Schedule 40 PVC pipe?
Schedule 40 PVC has a pressure rating of 120 psi to 810 psi, depending on pipe size, and temperature. At 73°F the pressures are as follows: 2″ = 280 psi. 3″ = 260 psi.