What does F3 mean on a Daikin air conditioner?
What does F3 mean on a Daikin air conditioner?
Outdoor unit discharge
F3 – Outdoor unit discharge temperature is too high – Insufficient refrigerant, clogged refrigerant piping or the discharge temperature thermistor could be faulty.
Where is Daikin fault code?
How To Find the Fault Code on a Daikin Mini Split System
- On the remote control find the Cancel button.
- Press and hold the Cancel button for 6 seconds.
- 00 will flash on the remote display.
- Press the Cancel button again once to cycle through the fault codes.
How do I reset my Daikin air conditioner?
Here’s how to reset a Daikin air conditioner remote:
- Locate the ‘ON/OFF’ button on your Daikin air con’s remote.
- Press and hold the button for 2 seconds.
- Press the ON/OFF switch once to stop operation.
- Press it a second time to start it again.
How do I fix Daikin error A0?
Re: Daikin A0 error, gah its a sauna in here! If you have dried all of the water out, you could try turning off the power to the condensing unit, waiting 20 seconds and then turn the power back on. If the fault has been removed, then you may be lucky and the system will reset.
How do I reset my Daikin wall AC controller?
What is a U4 fault on a Daikin air conditioner?
Daikin error code U4 indicates a communication error. There are 2 possible causes to this error code. Firstly, the wires between the indoor and outdoor units are not connected properly. Secondly, any PCB inside the condenser unit may not be connected properly as well.
What is U4 Fault in Daikin AC?
Press repeatedly until a long beep is produced.
SYSTEM | CODE | MEANING |
---|---|---|
U4 | FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT) | |
INDOOR UNIT | A1 | INDOOR PCB DEFECTIVENESS |
A5 | FREEZE-UP PROTECTOR | |
A6 | FAN MOTOR FAULT |
What are the error codes on a Daikin VRV IV?
Daikin VRV IV Error Codes. Error Codes. Problem. A1. EEPROM failure (indoor) A3. Drain system malfunction (indoor) A6. Fan motor malfunction (indoor)
How do I self diagnose an underline issue with my Daikin?
To self diagnose any underline issue with your Daikin product refer to the given set of error codes. The remote controller can receive relevant error codes from the indoor unit. When is held down for about 5 seconds, “00” blinks in the temperature display section. Press repeatedly until a long beep is produced.
Why choose Daikin technology?
An extensive product lineup utilizes Daikin technology for lower costs and environmental impact. Advanced inverter and heat pump technologies achieve greater efficiency and energy-savings at lower costs. A broad array of models allows the perfect match of style and performance to any interior space.